products/{category}

BEC Helthcare (I) Pvt. Ltd. H.O.: 39/878A2, YMJ West Lane, Opp. JLN Stadium, Palarivattom

Speak To Us Today 000 0000 0000

Pulmonology

Z018090 358

Agilia SP

1.Flow rate range: 0.1- 200 ml/h (depending on the syringe capacity - up to 1200 ml/h) 2.Flow rate accuracy: ± 1% on mechanism ; ± 2 % on syringes. 3.Syringe capacities: 5, 10, 20, 30/35, 50/60 CC. 4.Bolus: Manual bolus: Rate 50-1200 ml/h (50 ml/h increments). 5.Drug library: Initial drug list of 50 agents adjustable with Vigilant®, the IV Medication Safety Solution. Adjustment of the dilution,authorized infusion modes, default infusion modes, flow rate and bolus limits in m

INFSP7S 384

Infusia SP7s

1.Compatible with syringes of any brand 2.10ml-60ml 3.Automatic calibration for syringes of any brand 4.Three modes: Rate control mode, Time control mode and Dose-Weight control mode 5.Automatically detection of syringe types and settings 6.Three levels of alarm volume: high, medium and low. 7.Alarm functions: occlusion, empty, near empty, low battery, infusion over, syringe loose, etc 8.Three levels of the occlusion limited pressure: high, middle and low. 9.Waterproof class: IPX4 10. 8 hours

Z018290 309

Agilia SP PCA

1.Flow rate range: 0.1- 200 ml/h (depending on the syringe capacity - 0.1mL/h increment) 2.Flow rate accuracy: ± 1% on mechanism ; ± 2 % on syringes.3.Syringe capacities: 5, 10, 20, 30/35, 50/60 CC. 4.PCA Bolus:0 to 10 mL,0 to 100 mg,0 to 1000 mcg,0 to 100 mcg/kg, 0 to 10 mg/kg rate from 40 to 1200 mL/h 5.Lock out time: 1-120 mins 6. Patient Handset:Ergonomic design,waterproofwith light,with handstrap and beep emission 7.DPS: The Dynamic Pressure System - DPS

Z018290 357

TIVA Agilia

1.Flow rate range: 0.1-1200 ml/h (depending on the syringe capacity) 2.Flow rate accuracy:± 1% on mechanism ; ± 2 % on syringes. 3.Syringe capacities:5,10, 20, 30/35, 50/60 CC 4.Bolus: Manual bolus: Rate 50-1200 ml/h (50 ml/h increments). 5.Drug library: Drug parameters, infusion, bolus and loading dose parameters, authorised infusion modes,infusion mode per default. Inititial drug library of 50 drugs adjustable with Vigilant®, the IV Medication Safety Solutio

230

Respiratory Humidifier with built in electrical adaptor

*Three temperature and humidity settings *Integrated heater wire adapter *Ambient temperature sensor *Compatible with heated wire circuits
MR850 222

Respiratory Humidifier without built in electrical adaptor

*Adaptable. One device supports multiple therapies for adult, pediatric and neonatal patients *Reliable. Proven to consistently perform *Robust. Designed to withstand daily hospital use *Flow sensor technology. Automatic standby during periods of gas flow interruption *Condensation Control and Humidity Compensation. Automatic algorithms designed to reduce mobile circuit condensate
900MR805 228

Heater wire adaptor for RT-Series dual heated breathing circuits

Dual Heated Breathing Circuit Heater Wire Adaptor
900MR806 203

Electrical Adaptor - Single Heated, RT circuits

*For use with MR850 humidifier and RT-series breathing circuits *Also for use with HC550 humidifier *Includes surge protection
900MR858 214

Electrical Adaptor - Single Heated, Reusable, F&P

(900MR858) Inspiratory Heater Wire Adaptor for reusable circuits
213

Probe, Airway Temp & Flow (MR850) Right Angle (for use with 1.3m circuit)

900MR861 240

Probe, Airway Temp & Flow, for use with 1.8 m (RT330) circuits, MR850

900MR868 207

Probe, Airway Temp & Flow, for use with 1.1m (neonatal) circuits, MR850

Probe, Airway Temp & Flow, for use with 1.1m (neonatal) circuits, MR850